Fibaro - detector flood Detector Z-wave More
Detector flood detector FIBARO FGFS-101-ZW5 self-powered.
Detector flood detector and temperature Z-wave More.
(à modifier dans le module "Réassurance")
(à modifier dans le module "Réassurance")
(à modifier dans le module "Réassurance")
Detector flood detector and temperature FIBARO FGFS-101-ZW5 .
The detector flood detector can be powered by battery (approximately two years of battery life) or VDC voltage (12 or 24 )
An alarm flood is sent to devices in Z-Wave network or any controller of the alarm system, through the opening of a dry contact NF.
The flood sensor Fibaro FGFS-101-ZW5 is designed to be placed on the ground or on a wall with a probe for the detection of flood is extended by a wire connected to it.
The sensor has LED indicator to warn of an event and an alarm sound.
In addition, the sensor FGFS-101-ZW5 is equipped with a sensor reports tilt and movement to prevent a shift in position from its original location.
Flood sensor FGFS-101-ZW5 of Fibaro ongoing issue even when it drift to the surface of the water and continues to send the alarm signal in case ofmajor flooding water.
Features:
-
Detector flood detector and temperature Z-Wave
-
Compatible With Z-Wave More
-
Can be connected to any alarm system (terminal of potential-free output)
-
Can be installed anywhere - the contacts of the sensors of flooding can be extended with a wire
-
Powered on battery or dc power supply external
-
Theft Protection - tilt is reported on the Z-Wave network or alarm system's main controller
-
Two operating modes - flood / temperature sensor or just a temperature sensor
-
Tester network coverage Z-Wave integrated
-
Wireless update with the box, Fibaro Home Center 2
-
Very simple Installation - simply put on a surface prone to flooding
-
Type of module : Transmitter Z-Wave
-
Power supply : 12 - 24 VDC
-
Battery Type : CR123A
-
Battery life : 2 years
-
Consumption on external power : 0.4 W
-
The maximum current output capability (ALARM NC, TAMP NC) : 25mA
-
The maximum voltage supported in the output : 40V (AC or DC)
-
Frequency : 868,42 MHz
-
Transmission Distance : 50m free field, up to 40 m indoors
-
Dimensions : 72 x 28 mm (diameter x height)
-
Operating temperature : 0-40°C (-20°C to 70°C if external power supply)
-
Range of temperature measurement : -20 to 100°C
-
Measurement precision : 0.5°C (in a range of 0°to 40 ° C)
-
Standards : EMC directive 2004/108/EC and R&TTE 199/5/WE, RoHS 2011/65/EU LVD 2006/95/EC, EMC 2004/108/EC, R&TTE directive 1999/5/EC